Function and Benefits
- 128 * 128 dot matrix LCD display, standard menu operations
- Two measure mode: single and continuous
- Two group mode:direct(DIR) and general(GEN), readings will be lost when power off in direct mode. 80 readings can be stored for each group
- Zero point and multi-point calibration for each group
- Can recall, delete specified readings, or delete group readings
- Statistics display: mean, min., max. and standard deviation
- Three probe mode:auto, magnetic and eddy current
Specification
Model | EC-770 | EC-770S | EC-770SE |
---|---|---|---|
Probe type | Internal probe | Internal probe | External probe |
Accuracy | ±(2.5%+1μm) | ±(2%+1μm) | ±(2%+1μm) |
Measuring principle | Fe: Magnetic induction; NFe: Eddy currents | ||
Measuring range | 0~2000um | ||
Resolution | 0.1μm(0~99.9μm), 1μm(≥100μm) | ||
Power supply | Two 1.5V AAA batteries | ||
Readings memory | 320 readings for EC-770, 2000 readings for EC-770S / EC-770SE | ||
Unit | μm, mm, mils | ||
Storage environment | Temperature: -20~60°C | ||
Operation environment | Temperature: -20~60°C | ||
Dimension | 114mm*53mm*25mm | ||
Weight | 80g |